AOLT-4000N

GPON OLT (ETSI)

Applications

The AOLT-4000N is designed for carrier central office or MSO hub environments for enabling costeffective FTTx services.

Flexible Configuration

Two control card slots for 1+1 Control cards. Two switch slots for 1+1 Aggregation switch cards with redundant 10-GbE and 1-GbE Service Node Interfaces (SNI) uplinks. Ten line card slots.

Data Plane Connectivity

The AOLT-4000N's data plane consists of redundant 10-GbE connections to each card slot from the two dedicated double-width AOLT-4000-SWT slots in the shelf. Control Plane Connectivity The AOLT-4000N's control plane consists of redundant 1-GbE connections to each card slot from the two dedicated AOLT-4000-CTL slots.

Control Plane Connectivity

The AOLT-4000N's control plane consists of redundant 1-GbE connections to each card slot from the two dedicated AOLT-4000-CTL slots.

Specifications

Capacity

  • 2 slots Redundant control cards (AOLT-4000-CTL)
  • 2 slots (double-width) Redundant switch and timing cards(AOLT-4000-SWT)
  • 10 slotsGPON Line Cards (AOLT-4000-GLCP)

Management interface

  • ProtocolSNMPv2c, SNMPv3
  • Interface 10/100Base-T
  • Ports 2

Craft interface

  • USB 2.0 (type B connectors)

BITS/SSU clock

  • Two inputs75 ohms BNC and DB9
  • Two outputs 75 ohms BNC and DB9

Alarm

  • Five outputsDB15

Power supply

  • Dual inputIndividually controlled by circuit breaker -40.0 to +56.7 VDC

Cooling

  • Forced air cooling with fans

Dimensions

  • W x D x H 442 mm x 300 mm x 533 mm
  • Frame mounting 19 inch rack mount

Operating environment

  • Temperature -5 to +50ºC
  • Relative humidity 5% to 90% (non-condensing)

Compliance

  • EMC EN55022, CISPR-22 Class A
  • Safety EN60950, UL60950, CE, Optical IEC-60825-1 Class B Laser safety per G.664
  • Environmental EN300 019-1-3, QM-333 'B2" Category
  • Chassis EN300 119-4
  • Transient EN/IEC61000-4-4 (2001) Level 2
  • Radiant RF Immunity EN/IEC61000-4-3 (2002) level 2
  • Conducted Immunity EN/IEC61000-4-6 (2001) level 2
  • Surge EN/IEC61000-4-5 (2001) 0.5 KV (line)and 1.5 KV (earth)
  • ESD EN/IEC61000-4-2 (2001) Contact level 2 & air discharge level 3

  • For More Details Contact Alphion Sales

 

  • The information contained herein is for informational purposes only. Technical claims listed depend on various technical assumptions. Your experience with these products may differ if you operate the products in an environment which is different from the technical assumptions. Alphion reserves the right to modify these specifications without any prior notice. Alphion makes no warranties, expressed or implied, on the contained in this document.

MUMBAI HO

  • 302, Bonanza,"A" Wing,Sahar Plaza, J.B. Nagar, Andheri Kurla Road
  • Andheri (E). Mumbai - 400059
  • Ph: +91 22 40482800 F: +91 22 28323050
  • For other addresses Click Here

CHENNAI

  • Bascon Building, 7th Floor, 56/L, VenkataNarayana Road,
  • T. Nagar, Chennai - 600017.
  • Ph: +91 44 43455678 F: +91 44 43455666
  • For other addresses Click Here

FACE BOOK